Flow Control ValvesEC16-42 — Pressure Compensator, Priority-On-Demand with Static Load Sense |
Selection guide - similar valves. PDF file of this page. STP file for EC16-42. Request a quote. |
---|

SYMBOL:
DESCRIPTION
A screw-in, cartridge-style, priority-on-demand, pressure-compensator with a static load sense,
intended to provide priority flow in the required amount, while allowing excess flow to be used for
auxiliary functions.
OPERATION
The EC16-42 is a priority-type valve delivering pump flow at port 3. Port 4 will deliver required
priority flow regardless of load pressure. Excess flow exits at port 2. Port 1 is the load sense
port. All ports may be fully pressurized.
FEATURES
• Priority-on-demand
• Static load sense
• Hardened parts for long life.
• Quiet, modulated response.
• Industry-common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi) maximum
Input Flow: 150 lpm (40 gpm) with 10.3 bar (150 psi) compensating spring;
115 lpm (30 gpm) with 5.5 bar (80 psi) compensating spring
Priority Flow Rate: 80% of maximum input flow when priority pressure
exceeds bypass pressure. 50% of maximum input flow when bypass
pressure exceeds priority pressure.
Temperature: -40° to 100°C (-40° to 212°F) with Buna seals;
-26° to 204°C (-15° to 400°F) with fluorocarbon seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC16-4; See page 9.116.1_4w
Cavity Tool: CT16-4xx; See page 8.600.1
Seal Kit: SK16-4x-MMM; See page 8.650.1
A screw-in, cartridge-style, priority-on-demand, pressure-compensator with a static load sense,
intended to provide priority flow in the required amount, while allowing excess flow to be used for
auxiliary functions.
OPERATION
The EC16-42 is a priority-type valve delivering pump flow at port 3. Port 4 will deliver required
priority flow regardless of load pressure. Excess flow exits at port 2. Port 1 is the load sense
port. All ports may be fully pressurized.
FEATURES
• Priority-on-demand
• Static load sense
• Hardened parts for long life.
• Quiet, modulated response.
• Industry-common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi) maximum
Input Flow: 150 lpm (40 gpm) with 10.3 bar (150 psi) compensating spring;
115 lpm (30 gpm) with 5.5 bar (80 psi) compensating spring
Priority Flow Rate: 80% of maximum input flow when priority pressure
exceeds bypass pressure. 50% of maximum input flow when bypass
pressure exceeds priority pressure.
Temperature: -40° to 100°C (-40° to 212°F) with Buna seals;
-26° to 204°C (-15° to 400°F) with fluorocarbon seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC16-4; See page 9.116.1_4w
Cavity Tool: CT16-4xx; See page 8.600.1
Seal Kit: SK16-4x-MMM; See page 8.650.1
PERFORMANCE:


DIMENSIONS:


MATERIALS:
Cartridge: Weight: 0.56 kg (1.23 lb);
Steel with hardened work surfaces.
Zinc-plated exposed surfaces; Buna N
O-rings and TFE back-ups standard.
Standard Ported Body: Weight: 1.5 kg
(3.3 lb); Anodized high-strength 6061 T6
aluminum alloy, rated to 207 bar
(3000 psi); Ductile iron bodies available;
dimensions may differ. See page 8.016.1_4w
Cartridge: Weight: 0.56 kg (1.23 lb);
Steel with hardened work surfaces.
Zinc-plated exposed surfaces; Buna N
O-rings and TFE back-ups standard.
Standard Ported Body: Weight: 1.5 kg
(3.3 lb); Anodized high-strength 6061 T6
aluminum alloy, rated to 207 bar
(3000 psi); Ductile iron bodies available;
dimensions may differ. See page 8.016.1_4w
ORDERING CHART: