Directional Controls Optimized For Your Machine:

These mobile directional control valve solutions are tested to assure consistent work port flow regardless of inlet or load conditions.  They can be customized to match a number of flow ranges and are suitable for a wide variety of applications including wheel loaders, aerial lifts, backhoes, excavators, telehandlers, skidsteers and other off-highway equipment.

 



Not what you're looking for?
Flow Control
Directional Control
Direct Acting
Pilot Operated
  • Pressure Compensated - Direct Acting Cylinder Circuits- optimized and cost effective combination of valves working together to control a double-acting cylinder

     

    FLOW MAX PRESSURE
    WORK PORT A WORK PORT B
    0-4 gpm
    0-15 lpm
    0-3 gpm
    0-11 lpm
    3500 psi
    240 bar
    i-Design File
    0-4 gpm
    0-15 lpm
    0-5 gpm
    0-18 lpm
    3500 psi
    240 bar
    i-Design File
    0-5.5 gpm
    0-21 lpm
    0-5.5 gpm
    0-21 lpm
    3500 psi
    240 bar
    i-Design File
    0-6 gpm
    0-22 lpm
    0-6 gpm
    0-22 lpm
    3500 psi
    240 bar
    i-Design File
    Note: You must have the latest version of i-Design downloaded to utilize the above
    pre-configured i-Design ciruits.
    Pressure Compensated - Direct Acting Motor Circuits- optimized and cost effective combination of valves working together to control a bi-directional motor

     

    FLOW MAX PRESSURE
    WORK PORT A WORK PORT B
    0-3 gpm
    0-11 lpm
    0-3.5 gpm
    0-13 lpm
    3500 psi
    240 bar
    i-Design File
    0-5 gpm
    0-19 lpm
    0-4.5 gpm
    0-17 lpm
    3500 psi
    240 bar
    i-Design File
    0-5.5 gpm
    0-21 lpm
    0-5.5 gpm
    0-21 lpm
    3500 psi
    240 bar
    i-Design File
    0-7 gpm
    0-26 lpm
    0-6.5 gpm
    0-24 lpm
    3500 psi
    240 bar
    i-Design File
    Note: You must have the latest version of i-Design downloaded to utilize the above
    pre-configured i-Design ciruits.
  • Pressure Compensated - Pilot-Operated Cylinder Circuits- optimized and cost effective combination of valves working together to control a double-acting cylinder
    FLOW MAX PRESSURE
    WORK PORT A WORK PORT B PILOT PUMP TANK
    0-8.5 gpm
    0-32 lpm
    0-9 gpm
    0-34 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-9.5 gpm
    0-36 lpm
    0-10 gpm
    0-38 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-13 gpm
    0-49 lpm
    0-12.5 gpm
    0-47 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-20 gpm
    0-76 lpm
    0-19 gpm
    72 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-22 gpm
    0-83 lpm
    0-22 gpm
    0-83 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    Note: You must have the latest version of i-Design downloaded to utilize the above
    pre-configured i-Design ciruits.
    Pressure Compensated - Pilot-Operated Motor, Meter-In/Meter-Out Circuits- optimized and cost effective combination of valves working together to control a bi-directional motor
    FLOW MAX PRESSURE
    WORK PORT A WORK PORT B PILOT PUMP TANK
    0-12 gpm
    0-45 lpm
    0-11 gpm
    0-41 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-12.5 gpm
    0-47 lpm
    0-12.5 gpm
    0-47 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-13 gpm
    0-49 lpm
    0-13 gpm
    0-49 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-19 gpm
    0-72 lpm
    0-19 gpm
    0-72 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-22 gpm
    0-83 lpm
    0-20.5 gpm
    0-78 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    Note: You must have the latest version of i-Design downloaded to utilize the above
    pre-configured i-Design ciruits.
    Pressure Compensated - Pilot-Operated Motor Circuits, Restricted in Neutral- optimized and cost effective combination of valves working together to control deceleration of a bi-directional motor or symetrical meter-in/meter-out flow control
    FLOW MAX PRESSURE
    WORK PORT A WORK PORT B PILOT PUMP TANK
    0-9.5 gpm
    0-36 lpm
    0-11 gpm
    0-42 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-11 gpm
    0-42 lpm
    0-11 gpm
    0-42 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-13 gpm
    0-49 lpm
    0-12.5 gpm
    0-47 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-19 gpm
    0-72 lpm
    0-18 gpm
    0-68 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-23 gpm
    0-87 lpm
    0-21 gpm
    0-80 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    Note: You must have the latest version of i-Design downloaded to utilize the above
    pre-configured i-Design ciruits.
    Pressure Compensated - Pilot-Operated Motor Circuits, Meter-In Only- optimized and cost effective combination of valves working together to control a bi-directional motor with meter-in only control of flow
    FLOW MAX PRESSURE
    WORK PORT A WORK PORT B PILOT PUMP TANK
    0-12 gpm
    0-45 lpm
    0-12 gpm
    0-45 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-13 gpm
    0-49 lpm
    0-13 gpm
    0-49 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-13 gpm
    0-49 lpm
    0-13.5 gpm
    0-51 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-19.5 gpm
    0-74 lpm
    0-19 gpm
    0-72 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    0-22 gpm
    0-83 lpm
    0-22.5 gpm
    0-85 lpm
    400 psi
    28 bar
    3500 psi
    240 bar
    3500 psi
    240 bar
    i-Design File
    Note: You must have the latest version of i-Design downloaded to utilize the above
    pre-configured i-Design ciruits.