Electro-Proportional Valves — Flow Control HyPerformance™

HPV12-20 — Spool-Type, 2-Port, Normally Closed, Control Valve
  Selection guide - similar valves.
  PDF file of this page.
  Request a quote.

HPV12-20 Valve
U.S. Patent 8,253,063

HPV12-20 Valve symbol


A solenoid-operated, electrically-variable, two-port, normally closed when de-energized,
pressure-compensated, spool-type, proportional flow control valve for high pressure applications
up to 350 bar (5075 psi).

With inlet at port 1, the HPV12-20 will regulate flow out of port 2 regardless of system working
pressure with flow rate proportional to current applied to the solenoid.

• Continuous-duty rated coil.
• Hardened spool and cage for long life.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Waterproof E-Coils rated up to IP69K.
• 1000-hour salt-spray rated solenoid tubes.
• All HyPerformance products are tested to NFPA specification T2.6.1.
and are tested at a verification level of 90% and an assurance of 99%.

Operating Pressure: 350 bar (5075 psi); 10% Cycle Life: 420 bar (6090 psi)
  Note: all HyPerformance products are tested for 900K cycles at 350 bar and 100K cycles at 420 bar
Burst Pressure: 1241 bar (18,000 psi)
Regulated Flow: 0 to 68 lpm (0 to 18 gpm)
Internal Leakage: 0.38 lpm (0.10 gpm) fully closed at port 2 at zero current and 345 bar (5000 psi)
  pressure at port 1
Hysteresis: ± 1.9 lpm (0.50 gpm) maximum
Dither/PWM Frequency Range: 100 to 250 Hz
Electrical Parameters (with size 10 E-series coil): 2 standard voltage ratings:
 Coil Voltage
Threshold Current
Max. Control Current
 12 VDC
250 ±100 mA
1050 ±100 mA
24 VDC
125 ±50 mA
525 ±50 mA
Temperature: -54° to 107°C (-65° to 225°F) with PPDI Urethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
  7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC12-2, Variation 'A'; See page 9.112.1_2w
Cavity Tool: HCT12-2x-xx; See page 8.600.1
Seal Kit: HSK12-2U-O; See page 8.650.1
Coil Nut: Part No. 7004420

The EVDR Series controllers are recommended for use with most HydraForce proportional valves.
These newer electronic controllers are versatile, reliable, and easily configured and customized for
a wide range of applications. See the EVDR Product Selection Guide.
For other Electronic Controllers, see page 2.001.1_pdf




HPV12-20 Valve Flow chart



HPV12-20 Valve Dimensions



Cartridge: Weight: 0.29 kg (0.64 lb);
Steel with hardened work surfaces.
Zinc-plated exposed surfaces; Buna N
O-rings and polyester elastomer back-ups standard.

Ported Body: Weight: 2.74 kg
(6.05 lbs); H-Series Ductile iron.
Rated to 345 bar (5000 psi).
See page 8.012.1_2w.

E-Coil: Weight: 0.41 kg. (0.9 lb); Perfect
wound, fully encapsulated with rugged
external metal shell; Rated up to IP69K with
integral connectors.
See page 3.400.1_10-size.



HPV12-20 Ordering 10-size E-Coil