DESCRIPTION
A solenoid-operated, electrically-variable, two-port, normally closed when de-energized,
pressure-compensated, spool-type, proportional flow control valve for high pressure applications
up to 350 bar (5075 psi).

OPERATION
With inlet at port 1, the HPV12-20 will regulate flow out of port 2 regardless of system working
pressure with flow rate proportional to current applied to the solenoid.

FEATURES
• Continuous-duty rated coil.
• Hardened spool and cage for long life.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Waterproof E-Coils rated up to IP69K.
• 1000-hour salt-spray rated solenoid tubes.
• All HyPerformance products are tested to NFPA specification T2.6.1.
and are tested at a verification level of 90% and an assurance of 99%.

RATINGS
Operating Pressure: 350 bar (5075 psi); 10% Cycle Life: 420 bar (6090 psi)
  Note: all HyPerformance products are tested for 900K cycles at 350 bar and 100K cycles at 420 bar
Burst Pressure: 1241 bar (18,000 psi)
Regulated Flow: 0 to 68 lpm (0 to 18 gpm)
Internal Leakage: 0.38 lpm (0.10 gpm) fully closed at port 2 at zero current and 345 bar (5000 psi)
  pressure at port 1
Hysteresis: ± 1.9 lpm (0.50 gpm) maximum
Dither/PWM Frequency Range: 100 to 250 Hz
Electrical Parameters (with size 10 E-series coil): 2 standard voltage ratings:
 Coil Voltage
Threshold Current
Max. Control Current
 12 VDC
250 ±100 mA
1050 ±100 mA
24 VDC
125 ±50 mA
525 ±50 mA
Temperature: -54° to 107°C (-65° to 225°F) with PPDI Urethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
  7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC12-2, Variation 'A'; See page 9.112.1_2w
Cavity Tool: HCT12-2x-xx; See page 8.600.1
Seal Kit: HSK12-2U-O; See page 8.650.1
Coil Nut: Part No. 7004420

RECOMMENDED ELECTRONIC CONTROLLERS
The EVDR Series controllers are recommended for use with most HydraForce proportional valves.
These newer electronic controllers are versatile, reliable, and easily configured and customized for
a wide range of applications. See the EVDR Product Selection Guide.
For other Electronic Controllers, see page 2.001.1_pdf



 

 

PERFORMANCE:

HPV12-20 Valve Flow chart

 

DIMENSIONS:

HPV12-20 Valve Dimensions

 

MATERIALS:

Cartridge: Weight: 0.29 kg (0.64 lb);
Steel with hardened work surfaces.
Zinc-plated exposed surfaces; Buna N
O-rings and polyester elastomer back-ups standard.

Ported Body: Weight: 2.74 kg
(6.05 lbs); H-Series Ductile iron.
Rated to 345 bar (5000 psi).
See page 8.012.1_2w.

E-Coil: Weight: 0.41 kg. (0.9 lb); Perfect
wound, fully encapsulated with rugged
external metal shell; Rated up to IP69K with
integral connectors.
See page 3.400.1_10-size.

 

ORDERING CHART: