Valves - Electro-proportional Controls - Flow Control - Non-compensated - Spool Type - Normally Closed

PV72-33

NORMALLY CLOSED ELECTRO PROPORTIONAL VALVE CARTRIDGE

Overview

Description

PV72-33 is a solenoid operated, spool type, normally closed proportional flow control valve.

Operation

The valve provides regulated flow from port 3 to port 2 with input from port 1 blocked. Regulated flow is proportional to electric current applied to solenoid. The valve is intended for use with a pressure compensator at pressure differential not exceeding 175 psi [12 bar].

Features

  • Choice of two regulated flow ranges
  • Excellent linearity and hysteresis characteristics.
  • Hardened spool and cage for long life.
  • Optional control orifice sizes.
  • Optional coil voltages and terminations.
  • Efficient wet-armature construction.
  • Cartridges are voltage-interchangeable.
  • Unitized, molded coil design.
  • Coil waterproofing standard.
  • Manual Override option.
Pressure Ratings
Pressure rating:
  • 240 bar (3500 psi)
Proof pressure:
  • 345 bar (5000 psi)
Burst pressure:
  • 896 bar (13000 psi)
Flow Ratings
Flow rating:
  • 0 to 57 lpm (0 to 15.0 gpm)
Maximum internal leakage:
  • 0.38 lpm (0.1 gpm) Max at 100 current
Temperature Ratings
Operating fluid temperature:
  • -40 to 100 °C (-40 to 212 °F) With buna N seals
  • -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
  • -54 to 107 °C (-65 to 225 °F) With polyurethane seals
Storage temperature:
  • -40 to 70 °C (-40 to 160 °F)
Ambient temperature:
  • -40 to 70 °C (-40 to 160 °F)
Other Ratings
Corrosion protection:
  • 960 hr salt spray per ASTM b117
Fluids:
  • Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range:
  • 7.4 to 420 cSt
Maximum operating contamination level:
  • 18/16/13 per ISO 4406
Unit weight:
  • 0.40 kg (0.88 lb) Blank option
  • 0.44 kg (0.98 lb) "m" option
  • 0.55 kg (1.21 lb) "g" option
Internal wetted surface area:
  • 283 cm² (43.8 in²) Blank option
  • 348 cm² (53.9 in²) "m" option "g" option
Note:
  • With size 70 e-series and d-series coils
Maximum control current:
  • 1500 mA 12 V coil
  • 750 mA 24 V coil
Threshhold current:
  • 300 mA 12 V coil
  • 150 mA 24 V coil
Valve inductance:
  • 240 mH E-coil 12 V
  • 200 mH D-coil 12 V
  • 700 mH E-coil 24 V
  • 600 mH E-coil 24 V
Dither PWM frequency:
  • 100 to 250 Hz
PV72-33_Perf_Chrt(2022-02-24)
PV72-30_Dim_Dwg(2022-02-24)
NOTES:
  • Note: For D-series coils install both the upper and lower O-rings.
  • Note: For E-series coils install the upper O-ring only.
  • Note: Do not operate or pressurize the valve without installing the coil retaining nut. To ensure proper function, the coil nut must be installed to retain the coil.
  • Note: See installation instructions for detailed procedure.
Cavity:
Cartridge installation torque:
  • 47 N-m (35 ft-lb)
Coil nut torque:
  • 14 to 16 N-m (10 to 12 ft-lb)
Cover cap torque:
  • 7 to 9 N-m (5 to 7 ft-lb)
Orientation restriction:
  • None
PV72-33_Order(2022-02-24)

Model Options

PV72-33DE-H-J-L
D Max Regulated Flow
CODE
DESCRIPTION
A
80.6 lpm (21.3 gpm) Max Regulated Flow
B
58.7 lpm (15.5 gpm) Max Regulated Flow
E Manual Override
CODE
DESCRIPTION
BLANK
NONE
G
Variable Position Override, Red Knurled Knob with Cover Cap
M
Variable Position Override, Red Knurled Knob
H Line Body
CODE
DESCRIPTION
0
No Body
8T
Aluminum SAE 8
10T
Aluminum SAE 10
12T
Aluminum SAE 12
12TD
Ductile Iron SAE 12
6B
Aluminum BSPP 3/4" (6)
J Seal
CODE
DESCRIPTION
N
Buna-N
V
Fluorocarbon
P
Polyurethane
U
PPDI Urethane
L Coil
CODE
DESCRIPTION
0
No Coil
12DG
12 VDC, D-Coil, DIN 43650
12DL
12 VDC, D-Coil, Dual Lead Wires
12DL/W
12 VDC, D-Coil, Dual Lead Wires with Weatherpak
12DS
12 VDC, D-Coil, Dual Spade
12ER
12 VDC, E-Coil, Deutsch
12EY
12 VDC, E-Coil, Metri-Pack 150
24DG
24 VDC, D-Coil, DIN 43650
24DL
24 VDC, D-Coil, Dual Lead Wires
24DS
24 VDC, D-Coil, Dual Spade
24ER
24 VDC, E-Coil, Deutsch