Electro-Proportional Valves — Pressure Control

EHPR98-T35 — Proportional, Reducing / Relieving, Drop-in
  Selection guide - similar valves.
  PDF file of this page.
  STP file for EHPR98-T38.
  Request a quote.

EHPR98-T35 Valve

EHPR98-T35 Valve symbol


A drop-in, flange mount, direct-acting, hydraulic pressure reducing/relieving valve, which
can be infinitely adjusted across a prescribed range using a variable electric input. Pressure
output is proportional to DC current input. The E-coil is an integral part of the valve assembly,
and cannot be replaced or field-serviced.

The EHPR98-T35 allows free flow from 1 to 3 when no current is applied to the coil. When the
coil is energized, 2 is connected to 1. Increasing current applied to the coil will increase the
control (reduced) pressure proportionally. If pressure at 1 exceeds the setting induced by the coil,
pressure from 1 is relieved to 3. Note: Back pressure on port ? becomes additive to the pressure
setting at a 1:1 ratio.

• 10, 12, 20 or 24 VDC coils.
• 1000-hour salt spray protection.
• Economical drop-in style.
• Several push-on termination options.
• Higher inlet pressure option A available.
• Manual override and screen options.

Max. Inlet Pressure: 103 bar (1500 psi); If higher inlet pressure is required
   (103 bar/1500 psi to 241 bar/3500 psi) select the “A” option in the model code.
Max. Tank Pressure: 34.5 bar (500 psi); with Manual Override Option: 17.2 bar (250 psi)
Control Pressure at Max. Control Current: 20.7 bar (300 psi)
Max. Control Current: 1.38 amps for 10 VDC coil; 1.30 amps for 12 VDC coil;
   0.69 amps for 20 VDC coil; 0.65 amps for 24 VDC coil
Resistance: 4.2 ohm (10V), 5.1 ohm (12V), 17.0 ohm (20V), 19.3 ohm (24V)
Inductance: 80 mH (12V)
Hysteresis: less than 4% with 100 Hz PWM
Rated Flow: 5.7 lpm (1.5 gpm)
Max. Internal Leakage:
   De-energized: 75 ml/minute (4.58 cu. in./minute) at 25 bar (365 psi);
   200 ml/minute (12.2 cu. in minute) at 241 bar (3500 psi)
   Energized at I-Max.: 125 ml/minute (7.63 cu. in./minute) at 25 bar (365 psi);
   For Option A (higher inlet pressure):
   De-energized: 200 ml/min (12.2 cu.in./min at 241 bar (3500 psi);
   Energized at I-Max: 400 ml/min (24.4 cu.in./min.) at 241 bar (3500 psi).
Temperature: -40° to 120°C (-40° to 250°F) with standard Buna N seals
Ambient Air Temperature: -40° to 80°C (-40° to 176°F)
Environmental Rating: IP69K
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
   7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: Flange Mount
Mounting Screws: M4 x 0.7 x 12 Long; Part No. 4001015 (not provided with valve)
Cavity: VC-T009; See page 9.111.1; Cavity Tool: CT-T009R0-x-G; See page 8.600.1
Seal Kit: SKEHPR98-T3x; See page 8.650.1

The EVDR Series controllers are recommended for use with most HydraForce proportional valves.
These newer electronic controllers are versatile, reliable, and easily configured and customized for
a wide range of applications. See the EVDR Product Selection Guide.
For other Electronic Controllers, see page 2.001.1_pdf




EHPR98-T35 Valve Performance Chart


EHPR98-T35 Valve Performance Chart


EHPR98-T35 Valve Performance Chart

EHPR98-T33 Valve Dimensions



Cartridge including Coil: Weight: 0.20 kg
(0.44 lb); Steel with hardened work surfaces.
Zinc-plated exposed surfaces; HNBR O-rings standard. Coil is encapsulated, class H high temperature magnetwire, with zinc-nickel plated shell.

Ported Test Body: Consult Factory.

Mounting Screws: Must be ordered separately; Part no. 4001015