DESCRIPTION
A solenoid-operated, 2-way, normally closed, poppet-type, screw-in hydraulic cartridge
valve for blocking or load-holding in high pressure applications requiring low internal leakage.

OPERATION
When de-energized, the HSV10-20 acts as a check valve, allowing flow from 1 to 2, while blocking flow
from 2 to 1. When energized, the cartridges poppet lifts to open the 2 to 1 flow path. In this mode,
flow from 1 to 2 is severely restricted.
Operation of Manual Override Option: For normal operation (de-energized) the manual override pin
must be seated in the lower detent groove. To shift the valve manually, the operator pushes down on the
knob and rotates 180 in either direction. When the manual override is actuated, increased flow can be
achieved by pulling on the knob.

FEATURES
• Continuous-duty rated coil.
• Hardened seat for long life and low leakage.
• Optional coil voltages and terminations.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Waterproof E-Coils rated up to IP69K.
• Unitized, molded coil design.
• 1000-hour salt-spray rated solenoid tubes and coils.
• All HyPerformance products are tested to NFPA specification T2.6.1
  and are tested at a verification level of 90% and an assurance of 99%.

RATINGS
Operating Pressure: 350 bar (5075 psi); 10% cycle life: 420 bar (6090 psi)
   Note: all HyPerformance products are tested for 900K cycles at 350 bar and 100K cycles at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Flow: Up to 75.7 lpm (20 gpm)
Internal Leakage: 0.25 cc/minute (5 drops/minute) max. with 350 bar (5075 psi) at port 2
Temperature: -54° to 107°C (-65° to 225°F) with Urethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20C: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 350 bar (5075 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
   7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC10-2; See page 9.110.1_2w
Cavity Tool: HCT10-2xx; See page 8.600.1
Seal Kit: SK10-2U-O; See page 8.650.1
Coil Nut: Part No. 4553800

PERFORMANCE:

HSV10-20 Valve Performance Chart

  DIMENSIONS:
HSV10-20 Valve Dimensions

MATERIALS:

Cartridge: Weight: (without coil and nut)
0.19 kg. (0.41 lbs.); Steel with hardened work surfaces. Zinc-plated exposed surfaces; Urethane O-ring without back-up standard.

Ported Body: Weight: 1.19 kg.
(2.62 lbs.); H-series ductile iron. Rated to
345 bar (5000 psi).
See page 8.010.1_2w.

E-Coil: Weight: 0.41 kg. (0.9 lbs.); Perfect wound, fully encapsulated with rugged external metal shell; Rated up to IP69K with integral connectors.
See page 3.400.1_10-size.
  ORDERING CHART:

HSV10-20 Ordering Chart 10-size E-Coil


Selection guide - similar valves.