Solenoid-Operated On/Off Valve HyPerformance™

HSV12-20 — Poppet-Type, 2-Way, Normally Closed
  Selection guide - similar valves.
  PDF file of this page.
  Request a quote.

HSV12-20 Valve

SYMBOL:
HSV12-20 Valve symbol

DESCRIPTION
A solenoid-operated, 2-way, piloted, normally closed, poppet-type, screw-in hydraulic
cartridge valve, designed to function as a load holding or blocking valve in high-pressure
applications requiring low internal leakage.

OPERATION
When de-energized, the HSV12-20 blocks flow from ports 2 to 1. In this mode, the cartridge will
allow flow from ports 1 to 2 after overcoming the spring forces (see performance graph). When
energized, the valve will allow flow from ports 2 to 1 while severely restricting flow from ports
1 to 2.
Operation of Manual Override Option: The manual override feature is intended for
emergency use, not continuous duty operation. To operate, the manual override pin must be
seated in the lower detent groove. To shift the valve manually, the operator pushes down on the
knob and rotates 180 degrees in either direction. When the manual override is actuated,
increased flow can be achieved by pulling on the knob.

FEATURES
• Continuous-duty rated coil.
• Hardened seat for long life and low leakage.
• Optional coil voltages and terminations.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• Unitized, molded coil design.
• Manual override option.
• Waterproof E-Coils rated up to IP69K.
• Cost-effective cavity.
• All HyPerformance™ products are tested to NFPA specification T2.6.1.
and are tested at a verification level of 90% and an assurance of 99%.

RATINGS
Operating Pressure: 350 bar (5075 psi); 10% cycle life: 420 bar (6090 psi)
   Note: All HyPerformance products are tested for 900K cycles at 350 bar and 100K cycles
   at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Flow: 114 lpm (30 gpm)
Internal Leakage: 7 drops/minute with 350 bar (5075 psi) at port 2.
Temperature: -54° to 107°C (-65° to 225°F) with urethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 350 bar (3500 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
   7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC12-2; See page 9.112.1_2w
Cavity Tool: CT12-2xx; See page 8.600.1
Seal Kit: SK12-2U-0; See page 8.650.1
Coil Nut: Part No. 4553800

PERFORMANCE:

HV12-20 Valve Performance Chart

  DIMENSIONS:

HSV12-20 Valve Dimensions

MATERIALS:

Cartridge: Weight: (without coil and nut)
0.28 kg (0.61 lb); Corrosion-resistant zinc-nickel plated exposed surfaces. Steel with hardened work surfaces. Urethane seals without back-up rings standard.

Ported Body: Weight: 2.62 kg (1.18 lb); H-series ductile iron. Rated to 350 bar (5075 psi).
See page 8.012.1_2w.

E-Coil: Weight: 0.41 kg (0.9 lb); Perfect wound, fully encapsulated with rugged external metal shell; Rated up to IP69K with integral connectors.
See page 3.400.1_10-size.
  ORDERING CHART:

HSV12-20 Ordering Chart 10-size E-Coil

Selection guide - similar valves.
PDF file of this page. Request a quote.