HydraForce Logo

Solenoid-Operated On/Off Valve

SV38-30 — Spool-Type, 3-Way

Selection guide - similar valves.
PDF file of this page.
STP file for SV38-30.
Request a quote.


SV38-30 Valve

SYMBOL:SV08-30 Valve symbol

DESCRIPTION
A solenoid-operated, 3-way, spool-type, screw-in hydraulic directional cartridge valve.

OPERATION
When de-energized, the SV38-30 allows flow from 2 to 1 while blocking flow at 3.
When energized, the cartridge’s spool shifts to open from 3 to 2, while blocking flow out 1.
While port 1 may be fully pressurized, it is not intended to be used as the inlet.

Operation of Manual Override Option: To override, push button in, twist counterclockwise 180°. The internal spring will push the button out. In this position, the valve may be only partially shifted. To assure full override shift, pull the button out to its fullest extension and hold it in this position. To return to normal operation, push button in, twist clockwise 180°, and release. Override will be detented in this position.

FEATURES
• Continuous-duty rated coil.
• Hardened precision spool and cage for long life.
• Optional coil voltages and terminations.
• Efficient wet-armature construction.
• Cartridges are voltage interchangeable.
• All ports may be fully pressurized.
• Unitized, molded coil design.
• Manual override option.
• Optional waterproof E-Coils rated up to IP69K.
• Fully guided spool.
• Industry common cavity – Compact size.

RATINGS
Operating Pressure: 207 bar (3000 psi)
Flow: Up to 18 lpm (5 gpm)
Internal Leakage: Port 3, De-energized: 82 cc/minute (5 cu. in./minute) max. at 207 bar (3000 psi);
Port 1, Energized: 164 cc/minute (10 cu. in./minute) max. at 207 bar (3000 psi)
Temperature: -40° to 100°C (-40° to 212°F) with Buna seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: Standard Coil: 1.2 amps at 12 VDC;
0.13 amps at 115 VAC (full wave rectified).
E-Coil: 1.4 amps at 12 VDC; 0.7 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: See note on dimension drawing, and see page 9.020.1
Cavity: VC08-3; See page 9.108.1_3w
Cavity Tool: CT08-3xx; See page 8.600.1
Seal Kit: SK08-3x-MM; See page 8.650.1
Coil Nut: Part No. 7004400

PERFORMANCE:

SV38-30 Valve Performance Chart

  DIMENSIONS:SV38-30 Valve Dimensions

MATERIALS:

Cartridge: Weight: 0.13 kg. (0.28 lbs.);
Steel with hardened work surfaces.
Zinc-plated exposed surfaces; Buna N
O-rings and back-ups standard.

Standard Ported Body: Weight: 0.27 kg. (0.60 lbs.); Anodized high-strength 6061 T6 aluminum alloy, rated to 207 bar (3000 psi); Ductile iron bodies available; dimensions
may differ. See page 8.008.1_3w.

Standard D-Coil: Weight each: 0.27 kg.
(0.60 lbs.); Unitized thermoplastic encapsulated, Class H high temperature magnetwire. See page 3.200.1_10-size.

E-Coil: Weight: 0.14 kg. (0.3 lbs.); Perfect wound, fully encapsulated with rugged
external metal shell; Rated up to IP69K
with integral connectors.
See page 3.400.1_10-size.

 

ORDERING CHART:

SV38-30 Ordering Chart Manual Override Options


Selection guide - similar valves.
PDF file of this page. STP file for SV38-30. Request a quote.

Home | About HF | Browse Products | Find a Valve by Model No. | Literature | Support | Distribution | i-Design | Training | Careers
Copyright 2011 HydraForce, Inc. All rights reserved.