SYMBOL:
HSV12-40RB Valve symbol

 

DESCRIPTION
A high pressure, solenoid-operated, four-way, two-position, direct-acting, spool-type, screw-in
hydraulic cartridge valve intended for use in fan drive applications when shifting at maximum
rated flow is not necessary. The valve spool has an open transition state.

OPERATION
When de-energized, the HSV12-40RB allows flow from ports 3 to 4 and from ports 2 to 1.
When energized, the spool shifts to allow flow from ports 3 to 2, and from ports 4 to 1.

Operation of Manual Override Option: The manual override feature is intended for emergency
use, not continuous duty operation. To activate, turn the knurled adjustment knob clockwise until
the valve shifts. To deactivate, turn the adjustment knob counterclockwise until it stops.

FEATURES
• Manual override option.
• Hardened precision spool and cage for long life.
• Waterproof E‑Coils rated up to IP69K; optional voltages and terminations.
• Efficient wet-armature construction.
• Cartridges are voltage-interchangeable.
• Corrosion-resistant plating.
• All HyPerformance products are tested to the rigorous standards of the NFPA specification T2.6.1.
• All HyPerformance valves are tested at a verification level of 90% and an assurance of 99%.

RATINGS
Operating Pressure: 350 bar (5075 psi); 10% cycle life: 420 bar (6090 psi)
  Note: All HyPerformance products are tested for 900K cycles at 350 bar and 100K cycles at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Flow: 60 lpm (16 gpm) max. de-energized or energized. See performance graph titled
  Flow Rating vs. Load Pressure for shifting limits.
Max. Internal Leakage: Port 3 to 1, De-energized: 492 ml/minute (30 cu. in./minute.) at 350 bar (5075 psi);
  Port 3 to 1, Energized: 492 ml/minute (30 cu. in./minute.) at 350 bar (5075 psi);
Temperature: -54 to 107 °C (-65 to 225 °F) with urethane seals.
Minimum Pull-In Voltage: 10.2 VDC (12 VDC coil)
Response Time: Energized - 23 ms and De-Energized - 38 ms First indication of change of state
  with 100% voltage applied to the coil with flow at 24 lpm (6.3 gpm) with the inlet at port 3, ports
  2 and 4 looped, and port 1 to tank.
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
   7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC12-4; See page 9.112.1_4w
Cavity Tool: HCT12-4XX; See page 8.600.1
Seal Kit: HSK12-4U-000; See page 8.650.1
Coil Nut: Part No. 4555250

 

 

PERFORMANCE:

HSV12-40RB Performance Charts

 

DIMENSIONS:

HSV12-40RB Valve Dimensions

 

MATERIALS:

Cartridge: Weight: 0.4 kg (0.89 lb); Steel with hardened work surfaces. Corrosion-resistant
zinc-nickel plated exposed surfaces. Urethane seals without back-up rings standard

Standard Ported Body: Weight: 5.04 kg (0.916 lb); H-series ductile iron standard.
Rated to 350 bar (5075 psi).
See page 8.012.1_4w.

E‑Coil: Weight: 0.41 kg (0.9 lb); Perfect wound, fully encapsulated with rugged external metal shell. Rated up to IP69K with integral connectors.
See page 3.400.1_12-size.